Customization: | Available |
---|---|
Technology: | Infrared |
Style: | Zoom Lens |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
1.Real-time gas leakage visualization
2.Gas enhancement mode to detect a very small amount of gas leakage
3.WIFI can be connected to PID and FID, and the display screen can display the gas leakage concentration value
4.WiFi connectivity enables integration with mobile apps and centralized management platforms, and the APP can update the system in real time
5.High precision noncontact measurement-40ºC to + 350ºC temperature
6.Embedded operating system, similar to the UI design of a mobile phone and tablet, allows users to easily start working
7.USB (non-hazardous use), WiFi, HDMI (non-hazardous use) multiple data transmission modes High-resolution rotating LCD display screen
8.Adjustable angle high resolution viewfinder for high light
9.Lightweight type, a rugged design
10.Anti-fatigue ergonomic design
11.Application scenarios: petroleum and petrochemical plant, oil refinery, offshore oil and gas exploitation platform, natural gas treatment plant, natural gas storage and transportation, biological gas plant, chemical / chemical industry, coal mining industry, power station.
Project details | HW-330G | |
Detector | Solution ratio | 320×256 pixels |
Pixel pitch | 30μm | |
Spectral range | 3.2μm~3.5μm | |
NETD | ≤15mK@25ºC | |
Frame frequency | 60Hz | |
Camera lens | Angle of field | 24°×19° Or 14.5°×11.6° (Optional) Or 7°×6° (optional) |
F-number (F) | f 1.2/1.5 | |
Focus | Automatic / electric / manual focus ring | |
Image display | Display screen | 5.5-inch bright LCD touch screen, sunlight visual, resolution 10801920, can automatically adjust the brightness, automatic switch screen |
Eyepiece | A 0.49-inch HD OLED screen with a resolution of 19201080, with adjustable diopter and Angle. | |
Image adjustment | Automatically or manually adjust contrast and brightness | |
Image mode | Histogram, linear stretch, gas visual enhancement mode (GVETM), dual-band fusion mode (DB-FusionTM), in-drawing mode, visible light mode | |
Touch screen Automatic focus | support | |
Palette | 12 presets and 1 custom, with a palette reverse function. | |
Magnifier | Support for local amplification (size adjustable and removable) | |
Electron double | 1 to 12 times the continuous number change fold, can be expanded to 32 times. | |
Spatial resolution | The spatial resolution of the optional lens is 0.8 mrad and 0.4 mrad, respectively, supporting further distance target observation. | |
AI gas detection | With the AI algorithm, it can automatically mark the leaked gas | |
Measurement and analysis | Temperature range | -40ºC~+350ºC |
Accuracy | ± 2ºC or ± 2% (with a large absolute value) | |
Mobility point temperature measurement | Support 10 points | |
Mobility line temperature measurement | Support 10 lines | |
Temperature measurement in the movable area | Support for 25 circles and 25 rectangles | |
Temperature difference measurement | support | |
Isothermic line measurement | support | |
Maximum / low-temperature detection | Automatic maximum / minimum temperature detection: automatic maximum / minimum temperature on full screen / area / line temperature | |
Temperature alarm | Sound alarm / color alarm | |
Measurement update | Reflectance temperature, relative humidity, ambient temperature, target distance, and external infrared window compensation | |
Emission rate correction | From 0.01 to 1.0 | |
Probable gas | It can detect methane, ethane, propane, butane, pentane, ethylene oxide, ethane, bromomethane, bromide, bromoethane, chloromethane, 1-hexane, ethylene, propylene, isoprene, isobutene, 1,3-butadiene, benzene, toluene, xylene, trimylene, p-xylene, ethenylene, styrene, 1,2-xylene, methanol, ethanol, isopropanol and other common volatile organic gases. It can quickly detect volatile gas organic matter leakage points, and can image about 400 kinds of VOCs gases. | |
Gas detection | No need for auxiliary light sources such as lasers; when the distance is 2 meters and methane cylinder standard gas is used at a flow rate of 1 mL/min, the sample display should be able to observe the shape of the leaking gas cloud. No need for auxiliary light sources such as lasers; when the distance is 2 meters and propane cylinder standard gas is used at a flow rate of 0.5 mL/min and a concentration of 0.5% mol/mol, the sample display should be able to observe the shape of the leaking gas cloud. | |
Images together with video storage | Medium | 256GB removable TF card extended to 1TB, Class10 with hot swappable support |
Video storage mode | IR / visible light for simultaneous video recording | |
Image file format | Standard JPEG pictures, including digital photographs and full radiometric data | |
Image storage mode | Both infrared and visible images are stored in the same JPEG file | |
Radiation infrared video | Real-time radiation-based video is recorded and stored in the TF card | |
Unirradiated infrared video | H.264, store it in the TF card | |
Take photos regularly | From 3 seconds to 24 hours | |
Image annotation | Voice: up to 180 seconds, stored with the image Text: Select between the predefined templates |
|
Map depot | 1. It is supported to view the thumbnail / full map. You can edit / delete files and edit / delete / add text / voice notes in both this mode 2. In the full map mode, you can view text notes, play voice notes, conduct temperature measurement analysis, and take photos before and after switching 3. The fingerprint login user folder association is supported. The login user can only play back and view the files taken by the user |
|
Focusing | Hand self-integrated lens, support electric focus, autofocus, focus ring manual focus and touch screen autofocus and voice recognition autofocus function. | |
The super-resolution display | 640×512 or higher. | |
Visible light camera | Visible light camera | 8-megapixel, autofocus, built-in 2 LED fill lights. |
Laser designator | Laser classification | two stage |
Laser power | 1mW | |
Laser wave length | And 635nm in red | |
Power supply system | Battery type | Charging lithium battery |
Cell voltage | 7.2V | |
Battery capacity | ≥9.9Ah | |
Continuous steady work | Under the premise of meeting the maximum allowable error, the continuous and stable working time of the thermal imager should not be less than 4h. | |
Start time | No more than 5 minutes at room temperature. | |
Movement power supply | Independent control function of movement power supply: choose not to open the movement when the startup, and choose to close the movement separately in the startup state. | |
External power supply | Support USB 3.0 (Type C) real-time transmission data for analysis. | |
Charging type | Complete machine charging / battery charger charging | |
Power management | Power saving mode, automatic shutdown (never / 5 minutes / 10 minutes / 30 minutes), automatic stop screen (never / 5 minutes / 10 minutes / 30 minutes), power percentage display, low power alarm | |
Joggle | Video monitor 525 vidicon video out | HDMI |
Data interface | USB and WLAN: image, video transmission to the computer | |
4G | Support for remote real-time view of images and video | |
Other functions | Quantitative module | It can be linked with the gas quantitative analyzer and interconnected with the gas quantitative analyzer (FIID, PID, quantitative module) through WIFI and Bluetooth. The host can display and store the quantitative analysis instrument number, real-time VOCs concentration value, maximum concentration value and other information, and the concentration unit can be switched between ppm and mg/m3. |
Laser ranging module | Optional, 30m, 50m, 100m, 500m and 1km respectively. | |
Laser methane module | The device supports an optional laser methane module for quantitative analysis, displaying real-time concentration data on-screen and storing it alongside images and videos. | |
The fingerprint login | support | |
PDA | support | |
Hot spot | support | |
Fixed position | GPS+ Big Dipper | |
Suona | support | |
Mike | support | |
Drop-down menu | support | |
Speech recognition | support | |
Automatic gate | support | |
Time setting | support | |
Language setting | Chinese / English / Korean / Russian | |
Unit setting | Temperature (ºC / ºF) / distance (m / ft) | |
Environmental suitability | Working temperature | -20ºC~+60ºC |
Storage temperature | -40ºC~+80ºC | |
Working humidity | ≤95% | |
Cooling system operating noise | The noise value is 30dB(A). | |
Levels of protection | IP66 | |
Explosion-proof sign | Ex ic nC op is IIC T6 Gc | |
Surface | Hand shank | rotating knobs |
Weight | ≤2.7kg | |
Size | Not more than 290×175×185mm (including standard lens) | |
Tripod installation | Standard, 1 / 4-20 UNC | |
Cut-out box | Pull rod type safety box, protection level IP68. | |
Configure | Standard configuration | Infrared thermal imager (including standard lens), rechargeable lithium battery * 3, battery charger, power adapter, USB cable, HDMI cable, 256 GTF memory card, card reader, back strap, cleaning kit, user manual, safety box |
Apolegamy | telephoto lens, wide angle lens, laser range module, laser methane module |